RFS Sensing Redundancy switch


 

 The RFS 2150 provides up 2 (or4) 2x1 L band sensing switches for detecting the presence of RF (primary) and switching to backup on the loss of primary.It uses a DPDT RF relay with the off path terminated in 75ohm. The primary RF is filtered, amplified and detected to operate the relay.Whilst the input level is above the, preset, threshold the relay is energised and the primary signal is selected. If the signal falls below the threshold then the relay is de-energised and the secondary path is selected.Models are also available for 70MHz ±18MHz and for 52MHz

 

 
 Parameter  RFS 070  RFS 052  RFS 2150
 Operating Frequency  5 - 1000MHz  5 - 1000MHz  950 - 2150MHz
 Detected Frequency  70 ± 18MHz  52 ± 1MHz  950 - 2150MHz
 Return Loss  >14dB  >14dB  >12dB
 Insertion Loss  0.5dB  0.5dB  2dB
 Frequency Response  ±0.5dB  ±3dB  ±1.5dB
 Isolation  40dB  >40dB  >35dB
 RF Connectors  F type 75ohm (option BNC75, BNC50, SMA, N type )
 Power supplies   Auto ranging 100 - 240vAC 50/60Hz
 Local Control  Front Panel pots and manual switch
 Mechanical  1RU x19"wide x 12.5"deep
     